TECHNICAL DATA EPOXY COMPOSITE SYSTEM DESCRIPTION
ECS is a two-component epoxy system formulated to provide enhanced adhesion to
wood, glass reinforcing and other common laminating composite materials.
The two components must be thoroughly mixed prior to use in the ratio of:
* By volume - 4 parts resin to 1 part hardener
* By weight - 4.55 parts resin to 1 part hardener
For consistent results and to realise the ful structural potential of the
system, measuring accuracy should be within the range of + or - 5%. FEATURES
* Relatively short thin film cure time, enabling rapid laminate fabrication
* Alternative hardeners for summer or winter usage to ensure consistent handling
INTENDED USES
* Timber Preservation and Waterproofing* Structural adhesive
RECOMMENDATIONS FOR USE: TIMBER PRESERVATION AND WATERPROOFING
The application of ECS to timber components during vessel construction provides protection against water-
logging and rot infestation, a major cause of destruction of timber boats.
ECS, in sealing the surfaces of timber components, maintains the desired level of moisture content, thus
prolonging strength and low weight capabilities whilst improving the flexural strength and resistance to impact.
Depth of penetration wil vary dependant on the moisture content of the timber, which should be less than 12%.
For maximum penetration the first coat should be thinned with approximately 25% of Methylated Spirits. Do
not exceed 25% thinning. Apply liberal y with brush or rol er.
Al ow a minimum of 12-24 hours curing time between each coat.
Between coats lightly sand back the surface with a medium grit paper.
Second and third coats must NOT be thinned.
Ensure that end grain areas are completely saturated.
Screw and nail holes should be fil ed with an epoxy fil er after saturation. (i.e.ECS thickened with F12)
Coverage wil depend on the moisture content and nature of the timber.
P.O. Box 58 333, Greenmount, Auckland, NEW ZEALAND. Ph. (09) 274 0808 Fax. (09) 274 0500
E-mail:[email protected] Webpage. www.uroxsys.co.nz
STRUCTURAL ADHESIVE
A thickening agent must be added to the system to increase viscosity and ensure adequate "wet out" is
achieved (ie, Uroxsys F12). Use sufficient to gain a ‘gel’, unthickened epoxy wil leave the joint dry.
The type of thickening agent used should produce thixotrophy (i.e. resistance to flow) without increasing the
viscosity excessively. To this end the fumed silicas have been used extensively in the past, but with recent
advances in asbestos-free fibres it is now possible to obtain a thixotrope with the advantages of reinforcement
As these two types of thixotropes differ in efficiency, it is recommended that advice from the thickener supplier
be sought for application technique.
Do not clamp epoxy adhesive with too much pressure. It is necessary to ensure there is sufficient glue in the
joint, which is then held immobile by light clamping during the curing period. SHEATHING SYSTEM
Incorporating reinforcing materials such as glass cloth in the epoxy coating of timber craft provides strength,
impact and abrasion resistance. Such reinforcement should be used for al surfaces below the water line, and
Surfaces must be clean and dry, and any irregularities, holes or sharp corners fil ed or fil eted.
Precut glass to easily handled sizes, and coat surface with ECS using a brush or rol er.
If using 6oz cloth, al ow 2 square metres per litre of binder. In general, you need to use between 2.2 and 2.5
times the glass reinforcing weight per square metre for proper wet out.
Apply the fibreglass to the wet surface and push it into the binder using normal fibreglass application tools.
The cloth when properly wet wil become transparent whilst areas not impregnated retain the dry cloth
appearance. These dry areas require more binder.
With successive laminations the build can be increased to any desired level.
Upon obtaining the required build, the binder is al owed to cure and then sanded to remove protruding "glass
hair" and the surface glazed with unfil ed resin/hardener mix.
The final coat should consist of a high quality UV resistant paint. Refer to UROXSYS for recommendations. SEALING OF POROUS SUBSTRATES
ECS epoxy is highly cross-linked and forms an effective vapour barrier over porous substrates such as
The surface must be clean, dry and sound. When overlaying concrete with a high performance coating or a
bonded timber system, dry diamond grinding is a fast and effective method of preparing and trueing up the
The ECS epoxy should be thinned 10% with Methylated Spirits to ease rolling and applied at an application
rate of 6m² per litre with a mohair roller.
To be effective as a vapour barrier, there must be a continuous glossy film left on the surface. If this is not
achieved in one coat application, repeat the operation. If the epoxy is soaking away, it normally indicates a
low strength concrete (high free volume) probably caused by overwatering during laying. Watch also for
signs of rejection (pulling back/poor wetting) during application, as this indicates contaminated concrete,
which must be further cleaned/prepared before coating.
ECS can also be used for crack filling if there is no live load movement. Make a temporary dam with either
Plaster of Paris or self-adhesive foam strips either side of cracks, opening them a little with a grinding wheel
P.O. Box 58 333, Greenmount, Auckland, NEW ZEALAND. Ph. (09) 274 0808 Fax. (09) 274 0500
E-mail:[email protected] Webpage. www.uroxsys.co.nz
if possible to aid ingress. Pour unthinned ECS into the retained area and top up as epoxy migrates. Grind
CAUTIONS: MOISTURE
The cure of epoxy products can be affected by moisture, which reacts with the hardener to give a surface
This blooming can give a permanent loss of gloss, less than normal chemical and physical resistance at the
surface, and affect inter-coat adhesion if over-coated.
Take al reasonable steps to minimise the risk of water, moisture, or excessive humidity exposure during the
cure period (which may be several days in cold temperatures). HYGIENE:
Wear protective clothing, gloves are essential. Avoid contact with exposed skin. Before commencing work
TEMPERATURE:
Do not use this product at ambient temperatures lower than 10°C, as ful strength wil not develop reliably
Epoxy resins used in the manufacture of this product may thicken and crystal ise over time at low storagetemperatures. The product should be stored at not less than 10°C. If cold temperature crystal ising occurs, it
can be simply reversed by reconditioning the resin component by raising the temperature of the product to at least 35°C overnight, and thoroughly mixing with a power mixer whilst hot. Heating can be done by standing
the unopened containers in a smal room with a thermostat-control ed electric heater, or by standing the pails
in very hot water. Contact Uroxsys for specific advice.
This information is, to the best of our knowledge true and accurate, but any recommendations or suggestions
which may be made are without guarantee, since the conditions of use are beyond our control. Furthermore
nothing contained herein shal be construed as a recommendation to use any product in conflict with existing
patents covering any material or its use.
P.O. Box 58 333, Greenmount, Auckland, NEW ZEALAND. Ph. (09) 274 0808 Fax. (09) 274 0500
E-mail:[email protected] Webpage. www.uroxsys.co.nz
pregnancy. Women currently enrolled in Medicaid. appointment only at 236 E. Young Street. COMMUNITY/PERSONAL HEALTH Medicaid Targeted Case Management: Home visits by ENVIRONMENTAL HEALTH 1ST FLOOR 399-7250 Registered Nurses serving children ages 0-3 currently enrolled on Medicaid. 2ND FLOOR 399-7160 Cancer Screening for Women: Breast exam and pap smear. Vouchers are given fo